titleFor 'Availability', Room Types with Rate Code combination samples are shown in your documentation. Is it possible to send 'Availability' messages without using a Rate Codes attached?

You can send these messages without the rate code, you can enter RatePlanCode and/or InvTypeCode to identify a roomtype. Please see the specs located at OTA_HotelAvailNotifRQ.

 When When receiving update messages with only InvTypeCode, availability of all room types with the same InvTypeCode attached (regardless of the Rate Plan Codes) shall be updated as indicated in the messages.

When receiving update messages with only Rate Plan Code, availability of all room types with the same Rate Plan Code (different Room Codes) shall be updated as per indicated in the messages.

Please be aware of that the information in the latest message will be used. For example, if you send us the inventory of 10 for all Single Rooms, we will apply inventory of 10 to all Single Rooms. You then send us inventory of 20 for all room with Standard Rate Code attached, all rooms with the Standard Rate code attached will have their inventory set as of 20, including the Single Room - Standard.

...